網站首頁  ◇  產品展示    ◇  通用色譜柱 ◇   GC-PLOT柱 > Rt®-Alumina BOND/CFC Columns(熔融石英plot柱)

Rt®-Alumina BOND/CFC Columns(熔融石英plot柱)

更新時間:  2017-07-05

產品型號:  

產品報價:  

所  在  地:  北京市朝陽區望京西園222號星源國際D座1503室

產品特點:  Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures.

(聯系我們,請說明是在 北京明尼克分析儀器設備中心 上看到的信息,謝謝!)

產品概述

Rt®-Alumina BOND/CFC Columns (fused silica PLOT)

 

*       Improved inertness for halogenated compounds.

*       Highly selective alumina-based column, separates most CFCs.

*       High retention and capacity for CFCs.

Product Name:

Rt-Alumina BOND/CFC

Temp. Limits:

to 200°C

Length:

30m

Internal Diameter:

0.53mm

df (µm):

10μm

 

1. Highly selective for C1-C5 hydrocarbons; separates all unsaturated hydrocarbon isomers above ambient temperatures. 2. Reactivity of aluminum oxide stationary phase is minimized so that column response for polar unsaturates, such as dienes, is optimized. Column sensitivity or response ensures a linear and quantitative chromatographic analysis for these compounds. 3. Strong bonding prevents particle generation. The column can be used in valve switching operations, without release of particles that can harm the injection and detection systems. 4. The Rt®-Alumina BOND column is stable up to 200 °C. If water is adsorbed on the column, it can be regenerated by conditioning at 200 °C. Full efficiency and selectivity will be restored. 5. High capacity and loadability give exceptionally symmetric peaks; ideal for volatile hydrocarbon separations at percent levels, as well as impurity analyses at ppm concentrations.

Guaranteed Reproducibility Each Rt®-Alumina BOND column is tested with a hydrocarbon test mix to ensure proper phase thickness and selectivity. 1,3-Butadiene is used to calculate k (capacity factor), which is a measure of phase thickness. Selectivity is measured using retention indices for propadiene and methyl acetylene. The resolution of trans-2-butene and 1-butene is also verified. To measure coating efficiency, plates per meter are checked using 1,3-butadiene. Extensive testing assures reproducible retention times and predictable flow behavior column-to-column.

*       Improved inertness for halogenated compounds.

*       Highly selective alumina-based column, separates most CFCs.

*       High retention and capacity for CFCs.

The alumina adsorbent is ideal for retaining halogenated compounds, especially CFC (chlorinated flourocarbons, freons). It offers high selectivity, allowing a wide range of CFC isomers to be resolved at above ambient temperatures. The Rt®-Alumina BOND/CFC column is thoroughly deactivated to reduce the reactivity of alumina. Even though there is still some residual reactivity for some mono- or di-substituted halogenated hydrocarbons, the majority of these compounds can be accuray quantified from main stream processes or in impurity analyses.

 

 

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7
北京明尼克分析儀器設備中心

北京明尼克分析儀器設備中心

聯系人:薛海玲  電話:010-84723211  郵箱:xuehail@163.com  總部地址:北京市朝陽區望京西園222號星源國際D座1503室

研發中心:北京市平谷區中關村科技園區興谷A區平和街39號院(聯東U谷)22號樓C區

版權所有 © 2026 北京明尼克分析儀器設備中心  總流量:1083421  備案號:京ICP備10037012號-2

管理登陸  網站地圖  技術支持:化工儀器網

主站蜘蛛池模板: 盐源县| 息烽县| 图片| 仪陇县| 仪征市| 临湘市| 彰化县| 沙雅县| 托克托县| 吴忠市| 松桃| 沿河| 安阳县| 栖霞市| 霍城县| 玉山县| 高青县| 盐津县| 和平县| 五常市| 松桃| 黄龙县| 文昌市| 石渠县| 桦南县| 临高县| 信宜市| 滕州市| 遵化市| 韩城市| 绵阳市| 理塘县| 曲周县| 太仆寺旗| 文昌市| 肇源县| 盐边县| 陆丰市| 石台县| 牡丹江市| 江永县|